mon-fri 9-13 / 14.30-18.30
Gynecological chair with electric height adjustment and gas-spring seat with Trendelenburg. Dimensions: L 188 x W 65 x H from 70 to 105 cm.
The gynecological chair with adjustable seat H930_79 is designed for professional use in clinics, health centers, and medical offices, where a stable station, practical adjustments, and patient comfort during examinations and procedures are required. The chair features a modern structure with a steel frame and powder coating in white, a combination designed to ensure solidity and a tidy, professional appearance. The faux leather upholstery, available in various colors, allows the seat to be adapted to the aesthetics of the clinical environment while maintaining a comfortable surface.
The functional core of the H930_79 is the adjustable seat with gas springs, which allows positioning in Trendelenburg and anti-Trendelenburg to best manage patient posture. To support daily operations, you also find an adjustable backrest with gas springs (inclination 0°–75°) and electrically adjustable height, useful for adapting the station to the needs of the physician and patient management. Standard equipment includes leg rests (set) adjustable on all planes, detachable footrest, stainless steel basin, backrest cover, and 4 adjustable rubber feet for leveling the chair. Dimensions reach 188 cm in length with leg support (138 cm without support), with a width of 65 cm and an allowable load of 150 kg.
Note on heights: the chair can be configured with 4 adjustable feet (70–105 cm).
Choose a chair with an adjustable seat and electric height to improve examination management. Purchase the H930_79 chair now or request a quote for multiple supplies.
Technical features:
Structure: modern steel with powder coating
Frame: powder-coated steel
Structure color: White
Upholstery: faux leather available in various colors
Seat: adjustable with gas springs
Seat positions: Trendelenburg and anti-Trendelenburg
Backrest: adjustable with gas springs
Backrest inclination: 0° – 75°
Height: adjustable (electric adjustment)
Height with 4 adjustable feet: 70 – 105 cm
Footrest: detachable
Leg rests: set adjustable on all planes
Basin: stainless steel
Feet: 4 adjustable rubber feet for leveling the chair
Backrest cover: included
Length (with leg support): 188 cm
Length (without leg support): 138 cm
Width: 65 cm
Allowable load: 150 kg
Weight: 83 kg
Trendelenburg: 0° – 25°
Anti-Trendelenburg: 0° – 15°
Optional:
User benefits:
Adjustment: of patient posture with gas-spring seat in Trendelenburg and anti-Trendelenburg.
Improved: operational ergonomics thanks to the electrically adjustable height.
Positioning: rapid with adjustable backrest (0°–75°) via gas springs.
Station: more complete during the examination with stainless steel basin and dedicated accessories.
Stability: and correct setup with 4 adjustable rubber feet for leveling.
FAQ:
Does the seat support Trendelenburg and anti-Trendelenburg?
Yes, the seat is adjustable with gas springs and allows Trendelenburg (0°–25°) and anti-Trendelenburg (0°–15°).
How is the chair height adjusted?
The height is electrically adjusted.
What is the adjustable height of the feet?
With 4 adjustable feet, the height is 70–105 cm.
What accessories are included in the standard equipment?
Detachable footrest, adjustable leg rests, stainless steel basin, backrest cover, and 4 adjustable rubber feet.
What is the maximum weight capacity?
The allowable load is 150 kg.
Short buying guide:
When choosing a gynecological chair for the clinic, first evaluate the adjustments you truly need during the examination: if patient positioning is central, a seat with gas springs and Trendelenburg/anti-Trendelenburg capability like on the H930_79 helps you manage different postures with practicality. Then consider the physician’s ergonomics: the electrically adjustable height allows the station to be adapted to the type of procedure and reduces repetitive strain. Check the completeness of the equipment (leg rests, footrest, stainless steel basin) because an already accessorized chair simplifies the organization of the examination room. Finally, choose the configuration best suited to the space and movement: feet prioritize stability and leveling, while any configuration with swivel wheels changes the height range and can be useful when the chair needs to be moved.
Adjustable seat gynecological chair, electric height gynecological chair, gynecological examination chair, Trendelenburg gynecological chair, anti-Trendelenburg gynecological chair, faux leather gynecological chair, stainless steel basin gynecological chair, H930_79.
*Images are purely indicative.
*Upon request and subject to a quote, armrests, IV pole (4 hooks), wheels, foot switch, and detachable footrest with adjustable inclination angle are available.
| Length in millimeters | mm1,880.00 |
|---|---|
| Depth in millimeters | mm650.00 |
| Height in millimeters | mm1,050.00 |
| type height | variable |
| capacity | 150 kg |

Holity uses PayPal and credit transfer as methods of payment.
Credit Transfer
Paying by credit transfer the order will be handled only after a bank credit receiving confirmation.
Payment must be made within 7 days from date of order. Go past the deadline, the order will be automatically canceled. The bank transfer purpose must necessarily bring the order number, the order date and client name.
The products availability has to be judged only from the credited.
The payment must 'be made payable to: ' NAMITI SRL '
PayPal
Selecting the type of PayPal payment, you will be redirected to a page on the PayPal site where in you can enter with your email address and password and make payment.
Your financial data will not be shared with Holity but they will be handled directly by PayPal.
In case of order cancellation or rejection by Holity, the amount will be refunded to your PayPal account and Holity will be not responsible for delays and / or damage during repayment.
Upon delivery of the goods the customer is required to inspect:
In case of tampering and / or breaks the customer will immediately challenge the shipment and / or delivery putting the word "SUBJECT TO INSPECTION FOR GOODS ....." (give reasons) on the delivery receipt from the courier.
The customer then must report any damage within 7 (seven) days of receipt of goods in the manner prescribed by the operator chosen for the expedition. In case the customer fails to collect within 2 (two) working days of the goods ordered and present in storage at the warehouses of courier and / or the Company due to the repeated inability to deliver to the address specified by the customer with the order, will return the goods to stores in Namiti Ltd., with charge to the account of charges for transport and storage of goods, the customer may request a new shipment of the goods, upon payment of these expenses and the new shipping cost.