mon-fri 9-13 / 14.30-18.30

The work harnesses These are PPE used in fall protection systems. The choice must be made based on the activity, the required attachment points, the other components of the fall arrest system, and the operator's characteristics. The Holity catalog includes EN 361 harnesses for fall arrest and more complex models that also comply with EN 358 and EN 813 for positioning and suspension.
The standards associated with the harness indicate different functions and should not be considered interchangeable.
There EN 361 This applies to full body harnesses intended for fall arrest systems. The fall arrest points can be dorsal or sternal depending on the product's configuration and marking.
The harness must be used in conjunction with the other system components required for the activity, such as connections, fall arrest devices, and a compatible anchor point. Therefore, choosing a harness without considering the entire safety chain is not enough.
The models also comply with the EN 358 They can integrate a belt with lateral points intended for positioning or restraint. These points must not be used as attachments to arrest a fall when they are not intended for this function.
There EN 813 This refers to harnesses with leg loops used in activities involving suspension or positioning. The most complete Holity harnesses can include a ventral point and a padded belt, making them also suitable for rope access when used in the configuration intended by the manufacturer.
A higher number of points does not automatically mean greater safety. The configuration must match the maneuvers to be performed.
The Holity catalog offers both basic harnesses and professional models with 3 or 5 attachment points. Always check the function assigned to each point in the product manual.
A harness must be able to be properly adjusted to the operator's body size and the clothing worn while working. Holity models are available in different sizes and with adjustment systems that vary depending on the product.
Some Holity models are tested at 130 kg, others at 150 kg: this data should therefore not be generalized to the entire category.
The draft It is the free space required under the user to arrest a possible fall before impact with the ground or an obstacle.
There is no universal value that can be calculated from the harness alone. It is necessary to consider the connection device used, any energy absorber, the anchorage position, possible component extensions, the operator's height, and the margins indicated by the manufacturer.
EU Regulation 2016/425 requires that the instructions for fall protection PPE also provide the necessary information on the minimum space required under the user.
After a fall has been arrested, prolonged exposure to the harness can pose a serious risk. For this reason, fall protection must be accompanied by a recovery and rescue procedure suitable for the activity.
Harness padding and geometry can affect comfort, but they don't eliminate suspension risk. Anti-trauma stirrups can help a conscious user move and support their legs while awaiting recovery, but they are no substitute for a timely rescue plan.
Before use, the condition of the PPE must be checked according to the manufacturer's instructions, checking in particular the straps, seams, buckles, attachment points, labels and any fall indicators.
EN 365 requires periodic inspections by a competent person, at least once a year; environmental conditions, intensive use or manufacturer's instructions may require shorter intervals.
It is incorrect to state that the inspection must always be carried out by a technician authorized by the manufacturer: this requirement depends on the type of PPE and the manufacturer's specific instructions.
There is no 5 or 10 year lifespan that applies to any harness. Useful life, storage conditions and disposal criteria are established by the manufacturer and must be verified in the individual PPE manual.
A harness must be withdrawn from use if it is damaged, deformed, has incompatible contamination, has broken stitching, or has any other defects that make its safety questionable. After a fall arrest event, it must be taken out of service and the manufacturer's instructions must be followed before any further use.
Explore the selection of work harnesses on Holity and compare models by EN standards, attachment points, sizes, weight limit, adjustments and ergonomic features.
For construction companies, industrial maintenance, rope access work, rescue or professional supplies you can request a personalized quote indicating the expected activity, quantity and required configuration.
Do EN 361 and EN 358 indicate the same function?
No. EN 361 concerns full body harnesses for fall arrest; EN 358 concerns systems intended for work positioning and restraint.
Can a side attack be used to arrest a fall?
Not automatically. The EN 358 lateral points are normally intended for positioning. For fall arrest, the points specifically designated and marked for this function must be used.
How is the draft calculated?
It must be calculated considering the entire fall arrest system and the instructions for its components. There is no universal fixed margin valid for every configuration.
How often should the harness be checked?
The required checks must be carried out before use and a periodic inspection by a competent person at least every 12 months, or more frequently when required by the conditions of use or by the manufacturer.
Can the harness be reused after a fall?
It must be immediately withdrawn from service. Any subsequent handling must follow the manufacturer's instructions and the procedure established for the PPE in question.
How long does a fall arrest harness last?
The shelf life depends on the product and the conditions of use and storage. It is important to refer to the useful life and recall criteria indicated by the manufacturer, not to a generic limit applicable to all PPE.