The veterinary resuscitation lung ventilator is an advanced device designed to ensure effective respiratory support during emergencies. This model is equipped with a 10.4-inch touch screen display that offers an intuitive and easy-to-use interface. Its turbine air propulsion allows it to deliver an air flow of up to 190 liters per minute, ensuring optimal ventilation. With compact dimensions of 290 mm in length, 215 mm in depth and 245 mm in height, it is designed to be easily integrated into clinical environments. The ventilator offers a wide range of ventilation modes, including APCV, APCV-TV, PSV, PSV-TV (Auto Weaning), VC/VAC, V-SIMV+PS, P-SIMV+PS and CPAP/PSV, thus adapting to the different needs of the patient. It also includes special modes such as SIGH and Apnea BACK-UP (NIV PSV, NIV PSV-TV, CPAP/PSV) to manage apnea situations. Finally, a MANUAL mode is also available for personalized control of settings. This ventilator is designed to offer reliable and precise performance in veterinary resuscitation, making it an essential tool for professionals in the sector.
Technical specifications:
Turbine-powered lung ventilator
Dimensions: L. 290 x D. 215 x H. 245 mm
Weight: 5.5 kg
Power supply: 100 - 240Vac / 50 - 60Hz
Power consumption: Max 60 VA
External low voltage power supply: 12 Vdc / 7 A
Internal battery: 1 x 12Vdc - 4.2 Ah Ni-Mh battery
Ventilatory frequency V-SIMV and P-SIMV: From 1 to 60 bpm
Inspiratory time in SIMV: From 0.2 to 5.0 sec
I:E Ratios: From 1:10 to 4:1
Inspiratory pause: From 0 to 60 % of inspiratory time
Inspiratory pressure limit (Pinsp): From 2 to 80 cmH2O (depending on the set value of low and high pressure alarm)
Inspiratory flow acceleration: Only in pressure-based operating modes: 1, 2, 3, 4 (acceleration ramp slope) - (4 maximum acceleration)
PEEP: From OFF, 2 to 50 cmH2O
PEEP regulation: Microprocessor-controlled electro-valves
O2 concentration: O2-Air mixture enrichment via low pressure O2 inlet
Trigger detection method: Via sensor (Pressure or Flow)
Inspiratory flow (FLOW): 190 l/min
Automatic Flow-by
PS (support pressure): From 2 to 80 cmH2O (PSV, V-SIMV, P-SIMV)
SIGH VC/VAC mode: Frequency: from 40 ÷ 500 bpm (1 bpm step) // Amplitude: from OFF, 10 ÷ 100% of set tidal volume (10% step)
CPAP/PSV: Pressure: from 3 to 50 cmH2O
Patient circuits: 150 cm dual-tube circuits
MENU function, SET function
Function for Loop, Curves, Parameter Map display selection
INSP. hold (range 5.0 - 15.0 sec / 0.1 sec step)
EXP. hold (range 5.0 - 10.0 sec / 0.1 sec step)
MAN command (manual ventilation)
10.4” Touchscreen display
Display viewing area: 262x163 mm
On-display controls (Side keyboard for quick access to functions and encoder knob for: selection, setting and confirmation of physiological respiratory parameters; selection and direct activation of functions)
Displays and settings (Operating Mode setting; Display of alarm signals and messages; Setting and monitoring of physiological respiratory parameters; Display of graphs and additional respiratory parameters; MENU function for setting operating parameters; Activation of special functions; Display of operating mode, clock, date and time function; Software version display)
MENU function
SETUP settings
Trends: Up to 72 hours of all measured parameters
Events: Up to 2000 events can be recorded, including alarms
Patient data: Patient data can be set and deleted
Default parameters: Default parameters can be restored
SET function (settable physiological respiratory parameters): CPAP (cmH2O), Slope, I:E, RR (bpm), RRsimv (bpm), Pause (%), PEEP (cmH2O), Pinsp (cmH2O), PMax - Pmin - PS (cmH2O), SIGH (% - bpm), Ti (s), Ti Max (s), Tr. E (%), Tr. I (L/min - cmH2O), Vte - Vti (ml), BACK-UP parameters
Holity uses PayPal and credit transfer as methods of payment.
Credit Transfer
Paying by credit transfer the order will be handled only after a bank credit receiving confirmation. Payment must be made within 7 days from date of order. Go past the deadline, the order will be automatically canceled. The bank transfer purpose must necessarily bring the order number, the order date and client name. The products availability has to be judged only from the credited. The payment must 'be made payable to: ' NAMITI SRL '
PayPal
Selecting the type of PayPal payment, you will be redirected to a page on the PayPal site where in you can enter with your email address and password and make payment. Your financial data will not be shared with Holity but they will be handled directly by PayPal. In case of order cancellation or rejection by Holity, the amount will be refunded to your PayPal account and Holity will be not responsible for delays and / or damage during repayment.
Upon delivery of the goods the customer is required to inspect:
The number of packages delivered is as indicated in the transport document
The packaging is intact and not altered even in the closing strip
In case of tampering and / or breaks the customer will immediately challenge the shipment and / or delivery putting the word "SUBJECT TO INSPECTION FOR GOODS ....." (give reasons) on the delivery receipt from the courier.
The customer then must report any damage within 7 (seven) days of receipt of goods in the manner prescribed by the operator chosen for the expedition. In case the customer fails to collect within 2 (two) working days of the goods ordered and present in storage at the warehouses of courier and / or the Company due to the repeated inability to deliver to the address specified by the customer with the order, will return the goods to stores in Namiti Ltd., with charge to the account of charges for transport and storage of goods, the customer may request a new shipment of the goods, upon payment of these expenses and the new shipping cost.